Knowledge Management System Of Qinghai Institute of Salt Lakes,CAS
Positive Thermal Ionization Mass Spectrometric Analysis of Boron Isotopeon River/Rain Water with Low Content and Rich Organic Matter | |
He Mao-Yong; Xiao Jun | |
2011 | |
发表期刊 | CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
![]() |
卷号 | 39期号:4页码:552-555 |
关键词 | Organic Matter River/rain Water Boron Isotope Micro-sublimation |
摘要 | A method for separation and isotopic determination of boron with low content and rich organic matter in the river/rain water samples was developed. Samples were concentrated by ion exchange Amberlite IRA-743 resin. The concentrated solution was subsequently micro-sublimated for 12 h to eliminate the organic matters. Then the boron isotope ratio was determined by measuring positive Cs(2)BO(2)(+) thermal ions. The average recovery was between 97. 5% and 101. 2%. The results that were determined by positive thermal ionization mass spectrometry were closed to those by MC-ICP-MS. The precision of isotopic measurement for boron in river/rain water was better than 0. 05 parts per thousand. The results demonstrated that this method was extremely effective for elimination organic matter interference during boron isotopic analysis with low sample size, high precision and accuracy. A method for separation and isotopic determination of boron with low content and rich organic matter in the river/rain water samples was developed. Samples were concentrated by ion exchange Amberlite IRA-743 resin. The concentrated solution was subsequently micro-sublimated for 12 h to eliminate the organic matters. Then the boron isotope ratio was determined by measuring positive Cs(2)BO(2)(+) thermal ions. The average recovery was between 97. 5% and 101. 2%. The results that were determined by positive thermal ionization mass spectrometry were closed to those by MC-ICP-MS. The precision of isotopic measurement for boron in river/rain water was better than 0. 05 parts per thousand. The results demonstrated that this method was extremely effective for elimination organic matter interference during boron isotopic analysis with low sample size, high precision and accuracy. |
文献类型 | 期刊论文 |
条目标识符 | http://ir.isl.ac.cn/handle/363002/1879 |
专题 | 青海盐湖研究所知识仓储 |
推荐引用方式 GB/T 7714 | He Mao-Yong,Xiao Jun. Positive Thermal Ionization Mass Spectrometric Analysis of Boron Isotopeon River/Rain Water with Low Content and Rich Organic Matter[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2011,39(4):552-555. |
APA | He Mao-Yong,&Xiao Jun.(2011).Positive Thermal Ionization Mass Spectrometric Analysis of Boron Isotopeon River/Rain Water with Low Content and Rich Organic Matter.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,39(4),552-555. |
MLA | He Mao-Yong,et al."Positive Thermal Ionization Mass Spectrometric Analysis of Boron Isotopeon River/Rain Water with Low Content and Rich Organic Matter".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 39.4(2011):552-555. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[He Mao-Yong]的文章 |
[Xiao Jun]的文章 |
百度学术 |
百度学术中相似的文章 |
[He Mao-Yong]的文章 |
[Xiao Jun]的文章 |
必应学术 |
必应学术中相似的文章 |
[He Mao-Yong]的文章 |
[Xiao Jun]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论