ISL OpenIR  > 青海盐湖研究所知识仓储
High Precise Determination of Bromine Isotopic Ratios by Positive Thermal Ionization Mass Spectrometry Using Static Multicollection Based on Cs2Br+ Ions
Ma Yun-Qi1,2; Peng Zhang-Kuang1,3; Chen Yan-Jiao1,3; Yang Jian1,3; Xiao Ying-Kai1; Zhang Yan-Ling1
2016-02-01
发表期刊CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
卷号44期号:2页码:186-191
关键词Bromine Isotope Positive Thermal Ionization Mass Spectrometry Static Multicollection Cs2br++
摘要A high precise determination of stable bromine (Br) isotopic ratios was achieved by thermal ionization mass spectrometer (TIMS) triton with 8 kV accelerating voltage using static multicollection of Cs2Br+ ions. The effect of B and Cl content on the measurement of Br isotope was studied. The static multicollection method had many advantages, such as high precision ( external accuracy lies between 0.09 parts per thousand-0.18 parts per thousand), small amount of sample loading ( 10-20 mu g Br) and short acquisition time (just 8 min for 100 cycles). The results showed that the effect of co-existing Cl on the measurement of Br isotope ratio increased with the increase of Cl content, and that the presence of B made the determined bromine isotope ratio lower than that without B. The effect of the sample loading sequence on the results of the determined Br isotopic ratio was insignificant. Meanwhile, the four bromide of Br isotopic composition were determined, its delta Br-81 was between 0.61 parts per thousand-1.68 parts per thousand, showing a significant Br isotope fractionation.
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.isl.ac.cn/handle/363002/6297
专题青海盐湖研究所知识仓储
盐湖地质与环境实验室
作者单位1.Chinese Acad Sci, Qinghai Inst Salt Lakes, Lab Salt Lake Geol & Environm, Xining 810008, Peoples R China
2.Chinese Acad Sci, Qinghai Inst Salt Lakes, Salt Lake Chem Analyzing & Testing Ctr, Xining 810008, Peoples R China
3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Ma Yun-Qi,Peng Zhang-Kuang,Chen Yan-Jiao,et al. High Precise Determination of Bromine Isotopic Ratios by Positive Thermal Ionization Mass Spectrometry Using Static Multicollection Based on Cs2Br+ Ions[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2016,44(2):186-191.
APA Ma Yun-Qi,Peng Zhang-Kuang,Chen Yan-Jiao,Yang Jian,Xiao Ying-Kai,&Zhang Yan-Ling.(2016).High Precise Determination of Bromine Isotopic Ratios by Positive Thermal Ionization Mass Spectrometry Using Static Multicollection Based on Cs2Br+ Ions.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,44(2),186-191.
MLA Ma Yun-Qi,et al."High Precise Determination of Bromine Isotopic Ratios by Positive Thermal Ionization Mass Spectrometry Using Static Multicollection Based on Cs2Br+ Ions".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 44.2(2016):186-191.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Ma Yun-Qi]的文章
[Peng Zhang-Kuang]的文章
[Chen Yan-Jiao]的文章
百度学术
百度学术中相似的文章
[Ma Yun-Qi]的文章
[Peng Zhang-Kuang]的文章
[Chen Yan-Jiao]的文章
必应学术
必应学术中相似的文章
[Ma Yun-Qi]的文章
[Peng Zhang-Kuang]的文章
[Chen Yan-Jiao]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。