题名: Determination of Major, Minor Elements in the Samples of SrCO3 Productby X-Ray Fluorescence Spectrometry
作者: Wang Xiao-huan ;  董亚萍 ;  孟庆芬 ;  Bian Shao-ju ;  冯海涛 ;  刘鑫
刊名: SPECTROSCOPY AND SPECTRAL ANALYSIS
出版日期: 2009
卷号: 29, 期号:8, 页码:2268-2271
关键词: X-ray fluorescence spectrometry ;  Pressed power sample ;  Strontium
语种: In the present paper a method for the determination of strontium, barium, calcium, magnesium, silicon, iron, aluminum and sulfur in the product of strontium carbonate by X-ray fluorescence spectrometry with pressed powder sample preparation was developed, and the standard samples were synthesized by high purity reagent. As the contents of strontium in the product of strontium carbonate were very high, the phenomenon of spectrum-peak-saturated occurred and the count rate was overflowed according to the measuring condition which was automatically given by the software system of X-ray fluorescence spectrometry. As a result, the deviation of the measurement is greater. According to analyzing the measuring condition of strontium, a method was given for reducing the count rate by reducing the measuring power of strontium, thus' achieving the goal of measurement. When sulfate was measured with pressed powder sample, the results were enhanced with the increase in measuring number. In light of this situation, a method was proposed to solve the problem. As the self-forming characteristic of the product of strontium carbonate was not so well, it was very difficult to press the sample successfully. So, the condition of squash method involving the kinds of the adhesives, the mixing technique with powder sample and the pressing-time technique was discussed. During making the sample, it was found that the effects of pellet formation were better if the time could be delayed by 120 seconds. Matrix effect was corrected by alpha coefficient method, the accuracy of the method was evaluated by analysis of synthetic sample. Detection limits of 0.623-107.6 mg.g(-1) were obtained. The results were in good agreement with certified values with precision of < 2.5% RSD. In the present paper a method for the determination of strontium, barium, calcium, magnesium, silicon, iron, aluminum and sulfur in the product of strontium carbonate by X-ray fluorescence spectrometry with pressed powder sample preparation was developed, and the standard samples were synthesized by high purity reagent. As the contents of strontium in the product of strontium carbonate were very high, the phenomenon of spectrum-peak-saturated occurred and the count rate was overflowed according to the measuring condition which was automatically given by the software system of X-ray fluorescence spectrometry. As a result, the deviation of the measurement is greater. According to analyzing the measuring condition of strontium, a method was given for reducing the count rate by reducing the measuring power of strontium, thus' achieving the goal of measurement. When sulfate was measured with pressed powder sample, the results were enhanced with the increase in measuring number. In light of this situation, a method was proposed to solve the problem. As the self-forming characteristic of the product of strontium carbonate was not so well, it was very difficult to press the sample successfully. So, the condition of squash method involving the kinds of the adhesives, the mixing technique with powder sample and the pressing-time technique was discussed. During making the sample, it was found that the effects of pellet formation were better if the time could be delayed by 120 seconds. Matrix effect was corrected by alpha coefficient method, the accuracy of the method was evaluated by analysis of synthetic sample. Detection limits of 0.623-107.6 mg.g(-1) were obtained. The results were in good agreement with certified values with precision of < 2.5% RSD.
Citation statistics: 
内容类型: 期刊论文
URI标识: http://ir.isl.ac.cn/handle/363002/2099
Appears in Collections:青海盐湖研究所知识仓储(2014年之前)_期刊论文

Files in This Item:

There are no files associated with this item.


Recommended Citation:
Wang Xiao-huan,Dong Ya-ping,Meng Qing-fen,et al. Determination of Major, Minor Elements in the Samples of SrCO3 Productby X-Ray Fluorescence Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2009,29(8):2268-2271.
Service
 Recommend this item
 Sava as my favorate item
 Show this item's statistics
 Export Endnote File
Google Scholar
 Similar articles in Google Scholar
 [Wang Xiao-huan]'s Articles
 [Dong Ya-ping]'s Articles
 [Meng Qing-fen]'s Articles
CSDL cross search
 Similar articles in CSDL Cross Search
 [Wang Xiao-huan]‘s Articles
 [Dong Ya-ping]‘s Articles
 [Meng Qing-fen]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
  Add to CiteULike  Add to Connotea  Add to Del.icio.us  Add to Digg  Add to Reddit 
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2016  中国科学院青海盐湖研究所 - Feedback
Powered by CSpace