Positive Thermal Ionization Mass Spectrometric Analysis of Boron IsotopeUsing Static Multicollection of Cs2BO2+ Ions
He Mao-Yong; Xiao Ying-Kai; Ma Yun-Qi; Zhang Yan-Ling; Wang Xiu-Fang; Xiao Jun; Wei Hai-Zhen
2009
Source PublicationCHINESE JOURNAL OF ANALYTICAL CHEMISTRY
ISSN0253-3820
Volume37Issue:5Pages:703-706
Contribution RankSCI
KeywordPositive Thermal Ionization Static Multicollection Dicesium Metaborate
LanguageA static double collector system and "Zoom Quad" function in the Finnigan-MAT Triton TI thermal ionization mass spectrometer was used to analyse different amounts of the boric acid standard NIST SRM 951 and natural samples, such as coral and foraminifera. The main objectives of the study were to discuss the difference of precision, accuracy, sample amount as well as testing time between static multicollection method and conventional peak jumping method. The experimental result indicated that in the same precision and the accuracy, the static double method is easier to measure small amount of sample as low as 0.1 mu g, and reduces the data acquisition time to 20 min. The reproducibility of measured B-11/B-10 ratios of NBS 951 boric acid with static multicollection is B-11/B-10 = 4.05159 +/- 0.00023 (2 sigma(m), n = 10) for 0.1 g of B. Finally 0.1 g natural samples were analyzed with a good test. A static double collector system and "Zoom Quad" function in the Finnigan-MAT Triton TI thermal ionization mass spectrometer was used to analyse different amounts of the boric acid standard NIST SRM 951 and natural samples, such as coral and foraminifera. The main objectives of the study were to discuss the difference of precision, accuracy, sample amount as well as testing time between static multicollection method and conventional peak jumping method. The experimental result indicated that in the same precision and the accuracy, the static double method is easier to measure small amount of sample as low as 0.1 mu g, and reduces the data acquisition time to 20 min. The reproducibility of measured B-11/B-10 ratios of NBS 951 boric acid with static multicollection is B-11/B-10 = 4.05159 +/- 0.00023 (2 sigma(m), n = 10) for 0.1 g of B. Finally 0.1 g natural samples were analyzed with a good test.
Document Type期刊论文
Identifierhttp://ir.isl.ac.cn/handle/363002/2110
Collection青海盐湖研究所知识仓储
Recommended Citation
GB/T 7714
He Mao-Yong,Xiao Ying-Kai,Ma Yun-Qi,et al. Positive Thermal Ionization Mass Spectrometric Analysis of Boron IsotopeUsing Static Multicollection of Cs2BO2+ Ions[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2009,37(5):703-706.
APA He Mao-Yong.,Xiao Ying-Kai.,Ma Yun-Qi.,Zhang Yan-Ling.,Wang Xiu-Fang.,...&Wei Hai-Zhen.(2009).Positive Thermal Ionization Mass Spectrometric Analysis of Boron IsotopeUsing Static Multicollection of Cs2BO2+ Ions.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,37(5),703-706.
MLA He Mao-Yong,et al."Positive Thermal Ionization Mass Spectrometric Analysis of Boron IsotopeUsing Static Multicollection of Cs2BO2+ Ions".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 37.5(2009):703-706.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[He Mao-Yong]'s Articles
[Xiao Ying-Kai]'s Articles
[Ma Yun-Qi]'s Articles
Baidu academic
Similar articles in Baidu academic
[He Mao-Yong]'s Articles
[Xiao Ying-Kai]'s Articles
[Ma Yun-Qi]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[He Mao-Yong]'s Articles
[Xiao Ying-Kai]'s Articles
[Ma Yun-Qi]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.