ISL OpenIR  > 青海盐湖研究所知识仓储
Effective elimination of isobaric ions interference and precise thermal ionization mass spectrometer analysis for boron isotope
Wei, HZ; Xiao, YK; Sun, A; Zhang, CG; Li, SZ
2004-07-01
发表期刊INTERNATIONAL JOURNAL OF MASS SPECTROMETRY
卷号235期号:2页码:187-195
关键词Boron Isotopes Isobaric Ions Interference Ionization Depressor Thermal Ionization Mass Spectrometer
摘要An ionization depressor, 1% H3PO4 was used to eliminate the isobaric interference that has been of a great concern during the procedure of boron isotopic ratio analysis by thermal ionization mass spectrometer (TIMS). Our experiments have shown that it appears to be an effective method to completely restrain the formation of isobaric ions of CNO- and Cs2CNO+ in the ionization source of mass spectrometer. We have also discussed the optimum proportion of depressor to nitrite for precise analysis of boron isotopes in natural samples based on a conditional experiment. In this case, the pretreatment of boron extraction from natural samples is greatly simplified since it is not necessary to remove nitrite and organic matter completely. In virtue of the method, we determined boron isotope in different types of natural samples, and our results are consistent with previous reports. (C) 2004 Elsevier B.V. All rights reserved.
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.isl.ac.cn/handle/363002/5611
专题青海盐湖研究所知识仓储
中国科学院青海盐湖研究所
作者单位1.Chinese Acad Sci, Qinghai Inst Salt Lakes, Xining 810008, Peoples R China
2.Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China
推荐引用方式
GB/T 7714
Wei, HZ,Xiao, YK,Sun, A,et al. Effective elimination of isobaric ions interference and precise thermal ionization mass spectrometer analysis for boron isotope[J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY,2004,235(2):187-195.
APA Wei, HZ,Xiao, YK,Sun, A,Zhang, CG,&Li, SZ.(2004).Effective elimination of isobaric ions interference and precise thermal ionization mass spectrometer analysis for boron isotope.INTERNATIONAL JOURNAL OF MASS SPECTROMETRY,235(2),187-195.
MLA Wei, HZ,et al."Effective elimination of isobaric ions interference and precise thermal ionization mass spectrometer analysis for boron isotope".INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 235.2(2004):187-195.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wei, HZ]的文章
[Xiao, YK]的文章
[Sun, A]的文章
百度学术
百度学术中相似的文章
[Wei, HZ]的文章
[Xiao, YK]的文章
[Sun, A]的文章
必应学术
必应学术中相似的文章
[Wei, HZ]的文章
[Xiao, YK]的文章
[Sun, A]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。