ISL OpenIR  > 青海盐湖研究所知识仓储
Determination of Major, Minor Elements in the Samples of SrCO3 Product by X-Ray Fluorescence Spectrometry
Wang Xiao-huan1,2; Dong Ya-ping1; Meng Qing-fen1; Bian Shao-ju1; Feng Hai-tao1; Liu Xin1
2009-08-01
发表期刊SPECTROSCOPY AND SPECTRAL ANALYSIS
卷号29期号:8页码:2268-2271
关键词X-ray Fluorescence Spectrometry Pressed Power Sample Strontium Carbonate
摘要In the present paper a method for the determination of strontium, barium, calcium, magnesium, silicon, iron, aluminum and sulfur in the product of strontium carbonate by X-ray fluorescence spectrometry with pressed powder sample preparation was developed, and the standard samples were synthesized by high purity reagent. As the contents of strontium in the product of strontium carbonate were very high, the phenomenon of spectrum-peak-saturated occurred and the count rate was overflowed according to the measuring condition which was automatically given by the software system of X-ray fluorescence spectrometry. As a result, the deviation of the measurement is greater. According to analyzing the measuring condition of strontium, a method was given for reducing the count rate by reducing the measuring power of strontium, thus' achieving the goal of measurement. When sulfate was measured with pressed powder sample, the results were enhanced with the increase in measuring number. In light of this situation, a method was proposed to solve the problem. As the self-forming characteristic of the product of strontium carbonate was not so well, it was very difficult to press the sample successfully. So, the condition of squash method involving the kinds of the adhesives, the mixing technique with powder sample and the pressing-time technique was discussed. During making the sample, it was found that the effects of pellet formation were better if the time could be delayed by 120 seconds. Matrix effect was corrected by alpha coefficient method, the accuracy of the method was evaluated by analysis of synthetic sample. Detection limits of 0.623-107.6 mg.g(-1) were obtained. The results were in good agreement with certified values with precision of < 2.5% RSD.
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.isl.ac.cn/handle/363002/5888
专题青海盐湖研究所知识仓储
盐湖资源综合利用工程技术中心
盐湖资源与化学实验室
作者单位1.Chinese Acad Sci, Qinghai Inst Salt Lakes, Xining 810008, Peoples R China
2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Wang Xiao-huan,Dong Ya-ping,Meng Qing-fen,et al. Determination of Major, Minor Elements in the Samples of SrCO3 Product by X-Ray Fluorescence Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2009,29(8):2268-2271.
APA Wang Xiao-huan,Dong Ya-ping,Meng Qing-fen,Bian Shao-ju,Feng Hai-tao,&Liu Xin.(2009).Determination of Major, Minor Elements in the Samples of SrCO3 Product by X-Ray Fluorescence Spectrometry.SPECTROSCOPY AND SPECTRAL ANALYSIS,29(8),2268-2271.
MLA Wang Xiao-huan,et al."Determination of Major, Minor Elements in the Samples of SrCO3 Product by X-Ray Fluorescence Spectrometry".SPECTROSCOPY AND SPECTRAL ANALYSIS 29.8(2009):2268-2271.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wang Xiao-huan]的文章
[Dong Ya-ping]的文章
[Meng Qing-fen]的文章
百度学术
百度学术中相似的文章
[Wang Xiao-huan]的文章
[Dong Ya-ping]的文章
[Meng Qing-fen]的文章
必应学术
必应学术中相似的文章
[Wang Xiao-huan]的文章
[Dong Ya-ping]的文章
[Meng Qing-fen]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。